Performance Monitoring
Table 15-21
Parameter
gfpStatsTxFrame
gfpStatsRxCRCErrors
gfpStatsRxOctets
gfpStatsTxOctets
gfpStatsRxSBitErrors
gfpStatsRxMBitErrors
gfpStatsRxTypeInvalid
gfpStatsRxCIDInvalid
gfpStatsCSFRaised
ifInPayloadCrcErrors
ifOutPayloadCrcErrors
hdlcPktDrops
1. Applicable only for CE100T-8
2. Applicable only for CE1000-4

15.6.4.5 CE-Series Card POS Ports Utilization Window

The POS Ports Utilization window shows the percentage of Tx and Rx line bandwidth used by the POS
ports during consecutive time segments. The Utilization window provides an Interval drop-down list that
enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated
with the following formulas:
Rx = (inOctets * 8) / (interval * maxBaseRate)
Tx = (outOctets * 8) / (interval * maxBaseRate)
The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction
for the Ethernet port (that is, 1 Gbps). The maxBaseRate for CE-Series cards is shown in
page
Note
Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity.
15.6.4.6 CE-Series Card Ether Ports History Window
The Ethernet POS Ports History window lists past Ethernet POS ports statistics for the previous time
intervals. Depending on the selected time interval, the History window displays the statistics for each
port for the number of previous time intervals as shown in
parameters are defined in
OL-9217-01
CE-Series Card POS Ports Parameters (continued)
Definition
2
Number of transmitted GFP frames.
Number of packets received with a payload FCS error.
2
Number of GFP bytes received.
2
Number of GFP bytes transmitted.
Sum of all the single bit errors. In the GFP CORE HDR at the GFP-T
receiver, these are correctable.
Sum of all the multiple bit errors. In the GFP CORE HDR at the GFP-T
receiver, these are uncorrectable.
Number of receive packets dropped due to Client Data Frame UPI errors.
1
Number of packets with invalid CID.
Number of GFP Client signal fail frames detected at the GFP-T receiver.
1
Received payload CRC errors.
1
Transmitted payload CRC errors.
Number of received packets dropped before input.