Removing And Replacing Tier 2 Crus - Lenovo System x3630 M4 Installation And Service Manual

Hide thumbs Also See for System x3630 M4:
Table of Contents

Advertisement

SATA 1
SATA 0
Step 3.
Align the backplane with the slot on the optional rear hard disk drive cage.
Step 4.
Lower the backplane into the optional rear hard disk drive cage. Make sure the three alignment
pins securely engages the three holes on the hard disk drive cage.
SAS/SATA
backplane
Step 5.
Install the hot-swap hard disk drives in the optional rear hard disk drive cage (see "Replacing a
hot-swap hard disk drive" on page 178).
Step 6.
Install the server top cover (see "Replacing the server top cover" on page 321).
Step 7.
Reconnect the external cables; then, reconnect the power cords and turn on the peripheral devices
and the server.

Removing and replacing Tier 2 CRUs

You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type
of warranty service that is designated for your server.
The illustrations in this document might differ slightly from your hardware.
Removing a microprocessor and heat sink
Use this information to remove a microprocessor and heat sink.
Attention:
SATA 1
SATA 0
Alignment pins
Hard disk
drive cage
.
Chapter 6
Removing and replacing components
305

Advertisement

Table of Contents
loading