Lenovo System x3630 M4 Installation And Service Manual page 418

Hide thumbs Also See for System x3630 M4:
Table of Contents

Advertisement

SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0480
User Response
If the specified sensor is CMOS battery, replace the system battery. If the specified sensor is Planar
3.3V or Planar 5V, (trained technician only) replace the system board. If the specified sensor is Planar
12V, complete the following steps until the problem is solved:
1. Check power supply n LED.
2. Remove the failing power supply.
3. Follow actions in "Power Problems and Solving Power Problems".
4. (Trained technician only) Replace the system board. (n = power supply number)
80010204-1d01ffff : Numeric sensor [NumericSensorElementName] going low (lower critical)
has asserted. (Fan 1Aa Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d01ffff or 0x800102041d01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan n, which is indicated by a lit LED near the fan connector on the system
board.
2. Replace the failing fan. (n = fan number)
80010204-1d02ffff : Numeric sensor [NumericSensorElementName] going low (lower critical)
has asserted. (Fan 1Ab Tach)
This message is for the use case when an implementation has detected a Lower Critical sensor going
low has asserted.
May also be shown as 800102041d02ffff or 0x800102041d02ffff
404
Lenovo System x3630 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents