5. If the expansion unit has an extraction device (such as a thumbscrew or a
6. If additional expansion units are being installed, repeat steps 4 through 8 for
7. Follow the instructions provided with the expansion unit to install an option in
8. If this is the last expansion blade being installed, install the cover provided
9. Install the blade server into the BladeCenter unit (see "Installing the blade

Removing and replacing Tier 2 CRUs

Use this information to determine the guidelines for installing a Tier 2 CRU into
your blade server.
You may install a Tier 2 CRU yourself or request IBM to install it, at no additional
charge, under the type of warranty service that is designated for the server.
Some Tier 2 CRUs are available as both optional devices and replaceable
components. You can use the installation instructions for the Tier 2 CRU to install
the optional device.
The illustrations in this document might differ slightly from your hardware.

Removing a microprocessor and heat sink

Use this information to remove a microprocessor and heat sink from the blade
server. The microprocessor and heat sink assembly must be replaced by a trained
technician.
Read the following important guidelines before you remove a microprocessor that
is not faulty (for example, when you are replacing the system-board assembly).
If you are not replacing a defective heat sink or microprocessor, the thermal grease
on the heat sink and microprocessor will remain effective if you carefully handle
the heat sink and microprocessor when you remove or install these components.
Do not touch the thermal grease or otherwise allow it to become contaminated.
Notes:
1. Read the following important information before you remove a microprocessor
2. The microprocessor installation tool might become worn after several uses.
lever), use it to fully engage the expansion unit on the blade server; otherwise,
press the expansion unit firmly into the closed position until it clicks into place.
To install an option into the expansion unit, refer to the documentation
provided with the expansion unit.
each expansion blade; otherwise continue with step 11.
the expansion unit.
with the expansion unit (see "Installing the blade server cover" on page 53).
server in a BladeCenter unit" on page 50).
that is not faulty (for example, when you are replacing the system-board
assembly).
If you are not replacing a defective heat sink or microprocessor, the thermal
grease on the heat sink and microprocessor will remain effective if you
carefully handle the heat sink and microprocessor when you remove or install
these components. Do not touch the thermal grease or otherwise allow it to
become contaminated.
Make sure that the tool can hold the microprocessor securely if you are reusing
an existing microprocessor installation tool. Do not return the tool with other
parts that you are returning.
Chapter 5. Removing and replacing blade server components
81