Viewing A List Of Fatal System Exceptions; Clearing The List Of Fatal System Exceptions; Controlled Shutdown Of The Module - Avaya M770 User Manual

Multifunction switch
Hide thumbs Also See for M770:
Table of Contents

Advertisement

Viewing a list of fatal system exceptions

A fatal system exception occurs when the CPU detects an error such as a division by
zero, or accesses to non-existent memory. A fatal exception causes the M770 ATM
Switch to reboot. A breakpoint is a special type of exception which is invoked by the
M770 ATM Switch software when it detects an internal inconsistency.
To dump a list of fatal system exceptions, use the system breaklog command.
Command:
Output:
Note: The breaklog provides vital information for diagnosing why the M770 ATM
Switch has crashed. This information needs to be reported to Avaya Technical Support.

Clearing the list of fatal system exceptions

To clear the list of fatal system exceptions, use the
command.
Command:

Controlled shutdown of the module

This command is used for a controlled shutdown of a module, any connections that
still remain on the module will be lost. A warning to this effect is displayed and
confirmation is requested before the module is powered down.
To carry out a controlled shutdown of the module in preparation for a power down,
use the system halt command.
Command:
Output:
Avaya M770 ATM Switch User's Guide
M15-155s8:/>system breaklog
:
Filename
Line No:
pml_time:
Abs_time:
Stablised Count:
Reason:
epc:
badva:
M15-155s8:/>system breaklog clear
M15-155s8:/>system halt
This will stop the module, losing all connections - do
you want to continue (y/n)?
Chapter 17
Managing System Commands
lmaux.c
553
1234
Unknown
0
0000b024
c005dce4
c8681734
system breaklog clear
229

Advertisement

Table of Contents
loading

Table of Contents