Chapter 10
Managing PNNI Routing
Set PNNI SVCC timers
Use the following command to set the PNNI node SVCC timers:
Command:
Parameters:
Note: This request will set value for SVCC timers according to the index parameter.
Changes will take effect immediately.
PNNI Timers
Show PNNI node timers
Use the following command to show the PNNI node timers:
Command:
Examples:
The user is not expected to change any of these timers. However, if you need more
information about these timers you may refer to the PNNI specification
(af-pnni-0055.000), Annex E: Architectural Variables.
The <level> parameter is optional – if it is omitted, timers of all levels will be
displayed.
160
M15-155s8:/>route pnni config svcc set <level> <index>
<value>
<level> - internal PNNI level number: 1 is the physical
node
<index> - the index of the timer, to set all timers type
'all'
<value> - the value that the selected timer will receive
M15-155s8:/>route pnni config timers show <level>
Timers :
Name
-----------------------------------------------------------------
PtseHoldDown
HelloHoldDown
HelloInterval
HelloInactivityFactor
HlinkInactivityTime
PtseRefreshInterval
PtseLifeTimeFactor
RxmtInterval
RDelayedAckInterval
AvcrPm
10
AvcrMt
11
CdvPm
12
CtdPm
13
Index
Current
Default
Value
Value
1
10
10
2
10
10
3
15
15
4
5
5
5
120
120
6
1800
1800
7
200
200
8
5
5
9
10
10
50
50
3
3
25
25
50
50
Avaya M770 ATM Switch User's Guide
Range
Units
[
1 -
600]
100ms
[
1 -
600]
100ms
[
1 -
600]
secs
[
1 -
20]
fctr
[
1 -
600]
secs
[ 60 - 3600]
secs
[100 -
500]
%
[
1 -
60]
secs
[
1 -
600]
100ms
[
1 -
99]
%
[
1 -
99]
%
[
1 -
99]
%
[
1 -
99]
%