Chapter 3 Avaya M770 Hub Components ... 9 The Control Panel ... 9 Avaya M770 Hub - Rear Panel Components ... 11 The M-SPV/M-SPX Supervisor Module ... 12 Communication with the M-SPV/M-SPX ... 12 Communication with Internal Management ... 12 M-SPV/M-SPX Front Panel ...
Page 4
Removing an M-SPV/M-SPX ...18 Replacing a Fan... 18 Replacing a Backplane... 19 Chapter 5 Using Avaya M440 Gate Switch 6U Modules... 21 Permissible 6U Modules and their Location ... 21 Using the 6U Module Adapter ... 21 Index... 23 How to Contact Us ... 25 In the United States ...25...
List of Tables DRU Budget of DomainX Modules ... 5 Avaya M770 Control Panel LEDs ... 9 Avaya M770 Control Panel Ports ... 10 Avaya M770 Control Panel Buttons ... 10 M-SPV/M-SPX Front Panel LEDs ... 13 M-PS Status LED ... 14...
Page 8
List of Tables List of Tables Avaya M770 User’s Guide...
Green/yellow lead - Earth ground Ventilation The Avaya M770 hub has air vents on the rear and sides. In order to ensure proper ventilation and cooling, leave a space of at least 6 cm (2.5 inches) on all sides. Certification Avaya certifies that this product met its public specifications at the time of shipment from the factory.
Plug the equipment in to a different outlet so that the equipment and receiver are on different branch circuits. • Check that cover screws, connector screws, blanking panels, and ground connections are well secured. The manufacturer is not responsible for the interference caused by unauthorized modifications to the equipment. Avaya M770 User’s Guide...
Please refer to Installing the Cable Manager below for details. If you are installing the Avaya M770 in a rack, you can adjust the depth by fixing the enclosed Rack Mount plates (refer to Installing the Depth-Adjusting Plates below).
Figure 1.1 Attaching the Depth Adjusting Plate Decorative Edge Panels The two plastic side-panels can be removed to allow access to the screw holes. Simply unclip the panels and replace them. The panels are interchangeable. Avaya M770 User’s Guide...
The combination of Cell Switching and Frame Switching provides switching for ATM, Ethernet, Fast Ethernet, and Gigabit Ethernet. Note: The ATM functionality of the Avaya M770 is detailed in the M770 ATM Switch User’s Guide. Figure 2.1 The Avaya M770 Multifunction Switch Avaya M770 User’s Guide...
Introduction Architecture The Avaya M770 hub features distributed processing on each of the modules, so there is no single point of failure. Most of the switching takes place on the module itself; only when a packet must travel from one module to another does it traverse the backplane.
(M-SPV refers to either the M-SPV or the M-SPX in the following examples): The Avaya M770 allows a maximum of 100 Domain Resource Units (DRUs) for DomainXL (Left DomainX - slots 1-7) and the M-SPV, and 100 DRUs for DomainXR (Right DomainX - slots 8-14) and the M-SPV.
Page 16
• Blinking OPR LED of each module (can also indicate a module fault). • Via the Avaya M770 CajunView Manager NMS application. Check the DRU report window (in the Configuration drop-down Menu). • Using the “Set Show” command in the Zoom view of the Avaya M770 CajunView Manager. DRU Budget Information Window You can check the DRU budget information for your Avaya M770 hub via the CajunView...
Avaya M770 Management Architecture The back of the Avaya M770 hub has two slots which house the main and backup Avaya M770 Supervisor modules, called M-SPV/M-SPX. The Supervisor module, together with the CajunView network management system, provides a zoom view of the Avaya M770 hub and all resident modules, regardless of technology.
Field replacement of components is described in Chapter 4. The Control Panel The control panel is located at the top of the front of the Avaya M770. It contains eight LEDs, three reset switches and three ports. Figure 3.1...
• To allow connection of a terminal or modem for configuring the Supervisor module and Avaya M770 hub. Function Resets the M-SPV/M-SPX agent only. Resets the entire Avaya M770 hub, including the M-SPV/M- SPX. Function Module is functioning normally Module is faulty...
** Use an opened paper clip or other pointed object to press the Reset button Avaya M770 Hub - Rear Panel Components The M-SPV/M-SPX Supervisor Module, power supplies and fans are located on the rear of the Avaya M770. Figure 3.2 shows a schematic illustration of the component locations: Figure 3.2...
This 9U module is essential for the correct functioning of the Avaya M770. The module is located in the rear of the Avaya M770 (see Figure 3.2). Although the hub has full functionality with only one agent, it is recommended to install an additional module as a backup.
Sideband Port SB2-ETH Two RJ-45 Sideband ports, SB1-ETH and SB2-ETH, on the Avaya M770 hub front panel are supported by the M-SPX (see Figure 3.1). The M-SPV supports only the SB1-ETH port.
Installation Guide. M-PS Indicator In addition to the PS status LEDs on the control panel of the Avaya M770 hub, each M-PS has a LED indicator on its rear panel for viewing its status at a glance during insertion and replacement of M-PSs.
All those components except the backplanes are hot-swappable, so that the hub can remain operational while you are replacing them. You will need to disassemble the Avaya M770 completely to replace the backplanes. Figure 4.1 Replacing an M-PS, M-SPV/M-SPX or a Fan Avaya M770 User’s Guide...
For more detailed information about the M-PS please refer to the M-PS Installation Guide. Inserting an M-PS To insert a new M-PS, perform the following steps at the back of the Avaya M770 hub (see Figure 4.1): If you are inserting an M-PS unit into an empty slot, remove the blank panel covering the slot by unscrewing its four retaining screws.
Either of the two M-SPV/M-SPX modules can be replaced without powering down the Avaya M770 hub. If one slot is empty, insert the new module into the empty slot and wait one minute before removing the module you wish to replace. The new M- SPV/M-SPX automatically inherits the configuration of the main M-SPV/M-SPX within one minute.
Unfold the levers and gently slide the module out. Replacing a Fan Caution: The fan may rotate for a short while after it is removed from the Avaya M770. Note: Although one fan is sufficient to cool the Avaya M770, it is recommended to use two fans to ensure maximum resiliance.
Replacing a Backplane The Avaya M770 has two backplanes. The lower backplane serves the X-switch and Avaya M440 Gate Switch modules, while the upper backplane connects the Avaya M770 ATM modules. Each backplane is sent with a detailed Installation Guide. The location of each backplane in the hub is shown in Figure 4.2 below.
You can use the LSE-MON module only if you set its internal jumper to Clock Disable (applicable only to C/S version D and up). Using the 6U Module Adapter This section explains how to insert 6U Avaya M440 modules in the Avaya M770 hub using the optional adapters. Two types of adapters are available: M-LS1 single-slot 6U module M-LS2 dual-slot 6U module.
Chapter 5 Using Avaya M440 Gate Switch 6U Modules Figure 5.1 Inserting the 6U Module Avaya M440 Gate Switch 6U Module Note: It is also possible to insert and remove modules in an adapter which is already in the hub.
How to Contact Us To contact Avaya’s technical support, please call: In the United States Dial 1-800-237-0016, press 0, then press 73300. In the EMEA (Europe, Middle East and Africa) Region Country Albania +31 70 414 8001 Austria +43 1 36 0277 1000...
In the CALA (Caribbean and Latin America) Region Email: caladatasupp@avaya.com Hot Line:+1 720 4449 998 Fax:+1 720 444 9103 For updated information, visit www.avayanetwork.com, and click “Global Support Organization (GSO)”. Avaya M770 User’s Guide Local Dial-In Country Number Malaysia Zealand...