IFM Electronic CR0403 Programming Manual page 36

Hide thumbs Also See for CR0403:
Table of Contents

Advertisement

ifm
Programming Manual
ecomatmobile
System description
>
RUN state
A transition into this state is possible in the following cases:
from the INIT state (autostart) if the following conditions are met:
• The operating voltage has reached a minimum value. AND:
• The application program exists.
From the STOP state:
• via the CODESYS command RUN.
• The operating voltage has reached or exceeded a minimum value.
In the RUN state:
>
The runtime system is running.
>
The application program is running.
>
The LED flashes green with 2 Hz.
The LED can be controlled differently by the application program → FB
A transition from this state into one of the following states is possible:
• INIT (after power-on-reset)
• STOP
• ERROR
• FATAL ERROR
>
ERROR state
A transition into this state is possible in the following cases:
• if the supply voltage is too low.
In the ERROR state:
>
The outputs of the device are switched off.
>
Processing of the application program is stopped.
>
System parameters are saved.
>
The LED flashed red with 5 Hz.
A transition from this state into one of the following states is possible:
• INIT (after power-on-reset)
• RUN
• STOP
• FATAL ERROR
>
FATAL ERROR state
A transition into this state is possible in the following cases:
• memory error (RAM / Flash)
• exception error
• runtime system error
In the FATAL ERROR state:
>
The outputs of the device are switched off.
>
The application program is terminated.
>
The runtime system is terminated.
>
The LED lights red.
A transition from this state into one of the following states is possible:
• INIT (after power-on-reset)
BasicController (CR0403) Runtime System V03.02
36
2015-04-01
Software description
SET_LED
(→ page 198).