Parameters of the inputs
Parameter
ENABLE
CHANNEL
MODE
FILTER
>
Parameters of the outputs
Parameter
VALUE
RESULT
Possible results for RESULT:
Value
Description
dec | hex
0
00
FB is inactive
1
01
FB execution completed without error – data is valid
2
02
function block is active (action not yet completed)
3
03
function block is active – valid values not yet available
130
82
channel setting is invalid
132
84
mode setting is invalid
136
88
filter setting is invalid
141
8D
wire break occurred
142
8E
short to supply voltage occurred
144
90
Current at the input is too high
BasicController (CR0403) Runtime System V03.02
Data type
BOOL
BYTE
BYTE
BYTE
Data type
WORD
BYTE
174
ifm function elements for the device CR0403
Description
TRUE:
execute this function element
FALSE: unit is not executed
> Function block inputs are not active
> Function block outputs are not specified
Number of input channel (0...11)
0...11 for the inputs IN0...IN11
operating mode of the input channel:
0 = 0x00
off
3 = 0x03
voltage input
6 = 0x06
voltage input, ratiometric
7 = 0x07
current input
9 = 0x09
voltage input
(only for analogue evaluated inputs)
10 = 0x0A
binary input, plus switching (BL)
(only for analogue evaluated inputs)
11 = 0x0B
binary input, plus switching (BL) with diagnosis
(Namur)
12 = 0x0C
binary input, minus switching (BH)
18 = 0x12
resistance input
filter for the measurement on the input:
valid= 0...8
recommended = 4
→ chapter
Configure the software filters of the inputs
(→ page 49)
Description
current value or status of the input channel
feedback of the function block
(possible messages → following table)
2015-04-01
8105
0...10 000 mV
0...1 000 ‰
0...20 000 µA
0...32 000 mV
16...3 600 Ω
from HW state
AD:
16...30 000 Ω
8106