IFM Electronic CR0403 Programming Manual page 133

Hide thumbs Also See for CR0403:
Table of Contents

Advertisement

ifm
Programming Manual
ecomatmobile
ifm function elements
>
Parameters of the outputs
Parameter
N_MSGS
EMCY
RESULT
Possible results for RESULT:
Value
Description
dec | hex
0
00
FB is inactive
1
01
function block execution completed without error
8
08
FB is active – not yet processed
242
F2
Error: setting is not possible
BasicController (CR0403) Runtime System V03.02
Data type
DWORD
ARRAY [0..MAXEMCYMSGS]
OF T_EMCY
BYTE
133
ifm function elements for the device CR0403
Description
Number of accumulated messages
Emergency messages
The most recent entry is in index 0.
Structure of T_EMCY:
.NODEID
ID of the node from which the message came
.EEC
Emergency Error Code
.ER
Error register
.MSEF
Manufacturer Specific Error Code
MAXEMCYMSG = 10
feedback of the function block
(possible messages → following table)
2015-04-01
7925

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents