Parameters of the outputs
Parameter
REDSTOPLAMP
AMBERWARNINGLAMP
PROTECTLAMP
NUMBER
SPN
FMI
SPN_CM
OC
RESULT
MIL_FC
REDSTOPLAMP_FC
AMBERWARNINGLAMP_FC
PROTECTLAMP_FC
Possible results for RESULT:
Value
Description
dec | hex
0
00
FB is inactive
1
01
FB execution completed without error – data is valid
8
08
FB is active – no data was received
242
F2
Error: setting is not possible
BasicController (CR0403) Runtime System V03.02
Data type
BOOL
BOOL
BOOL
BYTE
WORD
BYTE
BOOL
BYTE
BYTE
BYTE
BYTE
BYTE
BYTE
162
ifm function elements for the device CR0403
Description
red stop lamp (for older projects only)
TRUE:
OFF
FALSE:
ON
Amber warning lamp (for older projects only)
TRUE:
OUT
FALSE:
ON
protect lamp (for older projects only)
TRUE:
OFF
FALSE:
ON
number of the DTCs received (0...8)
Suspect Parameter Number
Failure Mode Indicator
permissible values = 0...31 = 0x00...0x1F
conversion method
occurrence count
feedback of the function block
(possible messages → following table)
Status of the electronic component:
Malfunction indicatation light status and flash code:
0 = off
1 = on
2 = flash slowly
3 = flash quickly
Status of the electronic component:
red stop light status and flash code:
0 = off
1 = on
2 = flash slowly
3 = flash quickly
Status of the electronic component:
Yellow warning light status and flash code:
0 = off
1 = on
2 = flash slowly
3 = flash quickly
Status of the electronic component:
protection light status and flash mode:
0 = off
1 = on
2 = flash slowly
3 = flash quickly