IFM Electronic CR0403 Programming Manual page 77

Hide thumbs Also See for CR0403:
Table of Contents

Advertisement

ifm
Programming Manual
ecomatmobile
ifm function elements
>
Parameters of the outputs
Parameter
MATCHED_ID
DATALENGTHCOUNT
DATA
MORE_DATA_AVAILABLE
RESULT
Possible results for RESULT:
Value
Description
dec | hex
0
00
FB is inactive
1
01
function block execution completed without error
5
05
FB is being processed – still receiving
9
09
CAN is not active
242
F2
Error: setting is not possible
250
FA
Error: FiFo is full – data was lost
BasicController (CR0403) Runtime System V03.02
Data type
DWORD
BYTE
ARRAY [0..7] OF BYTE
BOOL
BYTE
77
ifm function elements for the device CR0403
Description
number of the data object identifier
= Data Length Count
number of the data bytes received
received data, (1...8 bytes)
TRUE:
further received data available in the FiFo
FALSE:
no further data available in the FiFo
feedback of the function block
(possible messages → following table)
2015-04-01
7617

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents