IFM Electronic CR0403 Programming Manual page 181

Hide thumbs Also See for CR0403:
Table of Contents

Advertisement

ifm
Programming Manual
ecomatmobile
ifm function elements
>
Parameters of the outputs
Parameter
OUTPUT
CURRENT
RESULT
Possible results for RESULT:
Value
Description
dec | hex
0
00
FB is inactive
1
01
FB execution completed without error – data is valid
2
02
function block is active (action not yet completed)
3
03
function block is active – valid values not yet available
128
80
undervoltage on VBBx
129
81
overvoltage on VBBx
130
82
channel setting is invalid
132
84
mode setting is invalid
136
88
filter setting is invalid
141
8D
a wire break was detected
(for binary output, plus switching (BH) with diagnosis)
142
8E
a short circuit was detected
(for binary output plus switching (BH) with diagnosis)
145
91
current at the output is too high
(for binary output plus switching (BH) with diagnosis and protection)
BasicController (CR0403) Runtime System V03.02
Data type
BOOL
WORD
BYTE
181
ifm function elements for the device CR0403
Description
TRUE:
output is activated
FALSE:
output is deactivated
only available for current controlable outputs:
current output current in [mA]
feedback of the function block
(possible messages → following table)
2015-04-01
8081