Parameters of the outputs
Parameter
LEN
DATA
RESULT
Possible results for RESULT:
Value
Description
dec | hex
0
00
FB is inactive
1
01
FB execution completed without error – data is valid
5
05
FB is active – no data received yet
32
20
SDO transmission aborted by client or server
(SDO abort code 0x80)
33
21
TIMEOUT elapsed
242
F2
Error: setting is not possible
255
FF
Error: not enough memory available for the consuming multiframe
BasicController (CR0403) Runtime System V03.02
Data type
DWORD
ARRAY [0..SDOMAXDATA] OF
BYTE
BYTE
116
ifm function elements for the device CR0403
Description
number of the bytes received
permissible values = 0x0000 0001...0x0000 0800 = 1...2 048
buffer memory for user data of the SDO data transmission
feedback of the function block