IFM Electronic CR0403 Programming Manual page 94

Hide thumbs Also See for CR0403:
Table of Contents

Advertisement

ifm
Programming Manual
ecomatmobile
ifm function elements
>
Parameters of the outputs
Parameters
RESULT
Possible results for RESULT:
Value
Description
dec | hex
0
00
FB is inactive
1
01
function block execution completed without error
14
0E
FB is active
CANopen manager configures devices and sends SDOs
15
0F
FB is active
CANopen manager is started
238
EE
Error: CANopen configuration is too large and cannot be started
239
EF
Error: CANopen manager could not be started
242
F2
Error: setting is not possible
BasicController (CR0403) Runtime System V03.02
Data type
BYTE
94
ifm function elements for the device CR0403
Description
feedback of the function block
(possible messages → following table)