ifm
Programming Manual
ecomatmobile
ifm function elements
>
J1939_SPEC_REQ_MULTI
= J1939 Specific Request Multiframe Message
Unit type = function block (FB)
Unit is contained in the library ifm_J1939_NT_Vxxyyzz.LIB
Symbol in CODESYS:
>
Description
J1939_SPECIFIC_REQUEST requests and receives a specific multiframe message from another
controller.
>
Parameters of the inputs
Parameter
EXECUTE
CHANNEL
PGN
DA
>
Parameters of the outputs
Parameter
PRIO
LEN
DATA
RESULT
Possible results for RESULT:
Value
Description
dec | hex
0
00
FB is inactive
1
01
FB execution completed without error – data is valid
5
05
FB is active – no data received yet
242
F2
Error: setting is not possible
BasicController (CR0403) Runtime System V03.02
Data type
BOOL := FALSE
BYTE
DWORD
BYTE
Data type
BYTE
WORD
ARRAY [0..1784] OF BYTE
BYTE
147
ifm function elements for the device CR0403
Description
FALSE  TRUE (edge):
execute function element once
otherwise: function element is not active
A function element already started is processed.
CAN interface (1...n) depending on the device
PGN = Parameter Group Number
allowed = 1...??? = 0x00000001...0x???
J1939 address of the requested device
Description
message priority (0...7)
Number of data bytes to be transmitted
allowed = 1...1 785 = 0x0001...0x06F9
Received data (1...1785 bytes)
feedback of the function block
(possible messages → following table)