Electrical Requirements
To Connect Electrical Service To
The Tumble Dryer
The following steps outline the procedure for
connecting the electrical service to the tumble dryer.
NOTE: The wiring diagram is located in the
junction box.
1. Install a circuit breaker as close to the tumble
dryer as possible. If more than one tumble dryer
is being installed, a disconnect switch or circuit
breaker should be provided for each. This will
make it possible to disconnect each tumble dryer
for maintenance purposes.
2. Connect the conduit-encased leads to the
disconnect switch, or circuit breaker. Connect the
wire leads to the appropriate labeled terminal on
the terminal block. The ground wire must be
connected to the ground connection as shown in
Figure 24.
46
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
3. Check the electrical service phase sequence
(three phase only) as follows:
a. Energize the electrical service (on reversing
tumble dryers, ensure nonreversing is
selected) and momentarily start the tumble
dryer. Check the direction of the cylinder
rotation. If the cylinder rotates clockwise
(viewed from the front), the phase sequence is
correct. If the cylinder rotates
counterclockwise, proceed with step b.
NOTE: When viewed from the front, the
fan should rotate clockwise on 050 and 075
series models and counterclockwise on F75
series models.
b. Disconnect and reverse any two service leads
on the terminal block (example: switch L2
and L3 on terminal block).
70457901ENR7