Grounding Instructions; For Ce Models Only - ALLIANCE CA050L Installation Operation & Maintenance

050 series 075 series 50 pound (22.7 kilogram) capacity 75 pound (34 kilogram) capacity
Hide thumbs Also See for CA050L:
Table of Contents

Advertisement

Electrical Requirements

Grounding Instructions

NOTE: To ensure protection against shock, this
tumble dryer MUST be electrically grounded in
accordance with the local codes, or in the absence
of local codes, with the latest edition of the National
Electrical Code ANSI/NFPA No. 70. In Canada the
electrical connections are to be made in accordance
with CSA C22.1 latest edition Canadian Electrical
Code, or local codes. Electrical work should be
done by a qualified electrician.
This tumble dryer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. This tumble dryer must
be connected to a grounded metal, permanent wiring
system; or an equipment grounding conductor must be
run with the circuit conductors and connected to the
appropriate ground location.
• Metal conduit and/or BX cable is not considered
ground.
• Connecting the Neutral from the electrical
service box to the tumble dryer ground screw
does not constitute a ground.
• A dedicated ground conduit (wire) must be
connected between the electrical service box
ground bar and tumble dryer ground screw.
44
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
To reduce the risk of electrical shock,
de-energize the electrical circuit being
connected to the tumble dryer before
making any electrical connections. All
electrical connections should be made by
a qualified electrician. Never attempt to
connect a live circuit.
CAUTION
Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation after
servicing.

For CE Models Only

All OPL (non-vend) models are factory-equipped with
an emergency stop button on the front panel. If the
emergency stop function is desired on coin-operated
models, an external emergency stop button may be
installed.
NOTE: Activation of the emergency stop switch
stops all machine control circuit functions, but
DOES NOT remove all electrical power from
machine.
W409R1
W071
70457901ENR7