11
10
9
NOTE: Refer to Table 11 for sizing of steam lines. Piping must also be sized accordingly for length of runs,
and number of elbows.
1
Supply
2
12 in. (305 mm) Riser
3
Shut-Off Valve
4
Condensate Return Line from Supply Line
5
Return
6
Check Valve
7
Vacuum Breaker (Optional)
Steam Pressure PSI (bar)
80-100 (5.3-6.9)
*Based on 6.9 bar.
70457901ENR7
1
8
7
6
Supply Pipe Diameter
3/4 in. NPT
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2
12
6
13
8
18 in. (457 mm) Drop
9
Solenoid Valve (Supplied with machine)
10
Steam Bonnet
11
Flexible Line
12
Union
13
Trap with Built-In Strainer
Figure 26
Minimum
Table 11
Steam Requirements
3
4
TMB2014N
Steam Trap Size*
Pounds Condensate/Hour
(Kilograms Condensate/Hour)
160 (72.6)
5
TMB2014N
53