Diagnostic Microprocessor Control

General Operation
The Diagnostic Microprocessor Control (DMP) is
designed to manage the drying and cooling cycles of
the tumble dryer. The controller is also programmed
from the factory with five different default programs
as described below. The operator has the flexibility to
select the time for the drying and the cool down cycles
and the drying temperature. The operator may also
select either reversing or nonreversing basket action
only if the tumble dryer is equipped for reversing. The
operator may also reprogram the default programs.
See Programming.
Default Programs
Programs
1 – Towels
2 – Sheets
3 – Misc-1
4 – Misc-2
5 – Extra Dry
NOTE: If an altered program is determined to be corrupted, the default program settings will be used.
Features
• Drying time: 0-60 minutes
• Cooling time: 2-60 minutes
• LED display of cycle time, set temperature, and
actual temperature
• Thermistor controlled temperature
• Safety tumble cycle
• Buzzer for end of cycle, audible alarm
• Reversing/Nonreversing selection
• Five user programmable programs
• RPM display – when equipped with rotational
sensor only
• Monitors the lint door switch operation
• Monitors the thermistor for operation
70457901ENR7
Dry Time (Min.)
Cool Time (Min.)
40
30
30
25
5
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Temp. Set Point
185º/195ºF
5
(85º/91ºC)
5
165ºF (74ºC)
5
150ºF (66ºC)
5
135ºF (57ºC)
2
150ºF (66ºC)
Table 15
The minimum drying time is 0 minutes, and the
minimum cooling time is 2 minutes. The maximum
drying or cooling time is 60 minutes. The drying
temperature may be set from 100ºF (38ºC) to
185º/195ºF (85º/91ºC). The drying time, cooling time,
or temperature may be modified during an operating
cycle.
If it is necessary to reset the drying and cooling times
for the current cycle, press STOP once to stop the
tumble dryer. Press STOP again to cancel the cycle.
If it is necessary to change programs during a current
cycle, press STOP once to stop the tumble dryer and
press STOP again to cancel the current cycle.
Operating Instructions
Reversing
No
Yes
No
Yes
No
71