Electrical Requirements
Model
Electric
To Connect Electrical Service To
The Tumble Dryer
The following steps outline the procedure for
connecting the electrical service to the tumble dryer.
NOTE: The wiring diagram is located in the
junction box.
1. Install a circuit breaker as close to the tumble
dryer as possible. If more than one tumble dryer
is being installed, a disconnect switch or circuit
breaker should be provided for each. This will
make it possible to disconnect each tumble dryer
for maintenance purposes.
2. Connect the conduit-encased leads to the disconnect
switch, or circuit breaker. Connect the wire leads
to the appropriate labeled terminal on the terminal
block. The ground wire must be connected to the
ground connection as shown in Figure 17.
44
Figure 17 (continued)
Ground and Terminal Block Locations
Terminal Block
Contactor
Box
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Ground
Figure 17
3. Check the electrical service phase sequence
(three phase only). If one of the power leads is a
"high leg," connect it to lead L3 in the tumble
dryer. The cylinder must rotate clockwise and the
fan must rotate counterclockwise (as viewed
from the front of the tumble dryer – with selector
switch in non-reverse position). If not,
interchange leads L1 and L2 in the tumble dryer
connection box.
Electrical
Service
TMB2337N
TMB2337N