Place the dryer in position, and adjust the legs until the
dryer is level from side to side and front to back.
Leveling legs can be adjusted from inside the dryer
with a 1/4 in. driver. All four legs must rest firmly on
the floor so the weight of the dryer is evenly
distributed. The dryer must not rock.
1
1
Dryer Base
2
Level
3
Leveling Leg
4
Rubber Foot
Figure 3
IMPORTANT: Unless completely assembled, DO
NOT slide the dryer unit across the floor. DO NOT
slide the unit once the leveling legs have been
extended, as the legs and the base could become
damaged.
512691R4
2
3
4
D690I
D690I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Step 2: Connect Dryer Unit Exhaust
System
WARNING
To reduce the risk of fire and combustion
gas accumulation the dryer MUST be
exhausted to the outdoors.
To reduce the risk of fire and the
accumulation of combustion gases, DO
NOT exhaust dryer air into a window well,
gas vent, chimney or enclosed, unventilated
area, such as an attic, wall, ceiling, crawl
space under a building or concealed space
of a building.
WARNING
This gas appliance contains or produces a
chemical or chemicals which can cause
death or serious illness and which are
known to the State of California to cause
cancer, birth defects, or other reproductive
harm. To reduce the risk from substances in
the fuel or from fuel combustion, make sure
this appliance is installed, operated, and
maintained according to the instructions in
this manual.
To reduce the risk of fire, DO NOT use
plastic or thin foil ducting to exhaust the
dryer.
To reduce the risk of fire, the exhaust duct
and weather hood MUST be fabricated of a
material that will not support combustion.
Rigid or flexible metal pipe is recommended
for a clothes dryer.
To reduce the risk of fire due to increased
static pressure, we do not recommend
installation of in-line secondary lint filters or
lint collectors. If secondary systems are
mandated, frequently clean the system to
assure safe operation.
IMPORTANT: Installing in-line filters or lint
collectors will cause increased static pressure.
Failure to maintain the secondary lint system will
decrease dryer efficiency and may void machine
warranty.
Installation
W604
W045
W115
W354
W048
W749