WARNING
To reduce the risk of electric shock, fire,
explosion, serious injury or death:
• Disconnect electric power to the tumble
dryer before servicing.
• Close gas shut-off valve to gas tumble
dryer before servicing.
• Close steam valve to steam tumble
dryer before servicing.
• Never start the tumble dryer with any
guards/panels removed.
• Whenever ground wires are removed
during servicing, these ground wires
must be reconnected to ensure that the
tumble dryer is properly grounded.
To reduce the risk of fire and electric
shock, check with a qualified serviceman
for proper grounding procedures.
Improper connection of the equipment
grounding conductor may result in a risk
of electric shock.
To reduce the risk of fire and electric
shock, if electrical supply is coming from
a three phase service, DO NOT connect a
"High Leg" or "Stinger Leg" to a single
phase machine. On a three phase
machine, if there is a "High Leg" or
"Stinger Leg" it should be connected to
L3.
70457901ENR7

Electrical Requirements

W002R1
W068
W069
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
IMPORTANT: Electrical connections must be
made by a qualified electrician using data on serial
plate, installation manuals and wiring diagram
provided with machine and according to local
codes. Install a circuit breaker as close to the
tumble dryer as possible. If more than one tumble
dryer is being installed, a circuit breaker must be
provided for each.
NOTE: Connect machine to an individual branch
circuit not shared with lighting or other equipment.
NOTE: 3 Phase Machines Only - Do not use fuses
to avoid the possibility of "single phasing" and
causing premature failure of the motors.
WARNING
In case of servicing (or putting the tumble
dryer out of order), disconnect the tumble
dryer from the main supply by switching
off the circuit breaker.

Wiring Diagram

The wiring diagram is located in the junction or
contactor box.
The wiring diagram part number is in the lower
portion of the electrical data on the serial plate.
W796
43