ALLIANCE CA050L Installation Operation & Maintenance page 21

050 series 075 series 50 pound (22.7 kilogram) capacity 75 pound (34 kilogram) capacity
Hide thumbs Also See for CA050L:
Table of Contents

Advertisement

To reduce the risk of severe injury, clearance of tumbler cabinet from combustible
construction must conform to the minimum clearances, and/or local codes and
ordinances.
NOTE: Shaded areas indicate adjacent structure.
1
0.5 in. (13 mm) recommended between machines for removal or installation
2
Allow 2-4 in. (51-102 mm) opening at top of machine to aid in removal or installation. A removable trim piece
may be used to conceal the opening; zero clearance allowed for trim.
3
4 in. (102 mm) maximum header thickness
4
12 in. (305 mm) minimum clearance permitted for remainder
5
Guard
6
Provision for make-up air
7
24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes
8
0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed
70457901ENR7
1
8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING
3
2
Figure 2
Installation
W770
4
5
6
7
TMB2242N