ALLIANCE CA050L Installation Operation & Maintenance page 29

050 series 075 series 50 pound (22.7 kilogram) capacity 75 pound (34 kilogram) capacity
Hide thumbs Also See for CA050L:
Table of Contents

Advertisement

Prepurge
Models
Time
(seconds)
18
CE and
Australia
1-3
All others
1
CE
1
Non-CE
and non-
Australian
18
Australia
(Continued)
70457901ENR7
Reset
Trial for
Lockout
Ignition
Condition
(seconds)
By:
10
025, 030,
035, 055:
Press reset
button on rear
of machine
T30, T45:
Press lighted
reset button
in rear
contactor box
10
Open loading
door
10
For models
(attempts to
with EO, RE,
ignite 3
RU or UO
times)
control
suffixes:
Press start on
control
keypad.
For models
with all other
control
suffixes:
Press and
hold reset
button on
junction box
until light
goes out.
10
Open loading
(attempts to
door
ignite 3
times)
10
025, 030,
035, 055:
Press reset
button on rear
of machine
T30, T45:
Press lighted
reset button
in rear
contactor box
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
t
(Continued)
Prepurge
Models
Time
(seconds)
23
Australia
If lockout condition persists, check that the manual
gas shut-off valve is in the ON position and that the
gas service is properly connected. If condition still
persists, remove tumble dryer from service.
8. Load the cylinder with a full load of clean rags
and run to remove oil or dirt from cylinder.
9. Check the airflow switch operation refer to
Adjustments section. The heating systems should
shut off when the lint panel is opened a
maximum of 1.5 inches (38 mm).
The airflow switch operation may be affected by
shipping tape still in place, lack of make-up air,
or an obstruction in the exhaust duct. These
should be checked and the required corrective
action taken before attempting to adjust the
airflow switch. To adjust the airflow switch, refer
to Adjustments section.
WARNING
Do not operate tumble dryer if airflow
switch is faulty. An explosive gas mixture
could collect in tumble dryer if airflow
switch does not operate properly.
Installation
Reset
Trial for
Lockout
Ignition
Condition
(seconds)
By:
23
For models
with EO, RE,
RU or UO
control
suffixes:
Press start on
control
keypad.
For models
with all other
control
suffixes:
Press and
hold reset
button on
junction box
until light
goes out.
W407R1
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct050nCu050lCa050nCu050nDr50g2-ba050lDr50g2-ba050n ... Show all