HP 6125XLG Configuration Manual page 209

Blade switch layer 2 lan switching
Table of Contents

Advertisement

The service provider assigns VLAN 100 to a company's VLANs 10 through 50.
VLAN 3000 is the dedicated VLAN of the company on the service provider network.
Configure QinQ on PE 1 and PE 2 to provide Layer 2 connectivity for CVLANs 10 through 50 over the
service provider network.
Configure VLAN transparent transmission for VLAN 3000 on PE 1 and PE 2 to enable the hosts in VLAN
3000 to communicate without using an SVLAN.
Figure 54 Network diagram
Site 1
VLANs 10 to 50, 3000
Configuration procedure
1.
Configure PE 1:
# Configure Ten-GigabitEthernet 1/1/5 as a trunk port, and assign it to VLANs 10 through 50,
100, and 3000.
<PE1> system-view
[PE1] interface ten-gigabitethernet 1/1/5
[PE1-Ten-GigabitEthernet1/1/5] port link-type trunk
[PE1-Ten-GigabitEthernet1/1/5] port trunk permit vlan 100 3000 10 to 50
# Configure VLAN 100 as the PVID of Ten-GigabitEthernet 1/1/5.
[PE1-Ten-GigabitEthernet1/1/5] port trunk pvid vlan 100
# Enable QinQ on Ten-GigabitEthernet 1/1/5.
[PE1-Ten-GigabitEthernet1/1/5] qinq enable
# Configure Ten-GigabitEthernet 1/1/5 to transparently transmit frames from VLAN 3000.
[PE1-Ten-GigabitEthernet1/1/5] qinq transparent-vlan 3000
[PE1-Ten-GigabitEthernet1/1/5] quit
# Configure Ten-GigabitEthernet 1/1/6 as a trunk port, and assign it to VLANs 100 and 3000.
[PE1] interface ten-gigabitethernet 1/1/6
[PE1-Ten-GigabitEthernet1/1/6] port link-type trunk
[PE1-Ten-GigabitEthernet1/1/6] port trunk permit vlan 100 3000
[PE1-Ten-GigabitEthernet1/1/6] quit
2.
Configure PE 2:
# Configure Ten-GigabitEthernet 1/1/5 as a trunk port, and assign it to VLANs 10 through 50,
100, and 3000.
<PE2> system-view
PE 1
XGE1/1/6
VLANs 100 and 3000
XGE1/1/5
Service provider network
CE 1
PE 2
XGE1/1/6
XGE1/1/5
CE 2
VLANs 10 to 50, 3000
199
Site 2

Advertisement

Table of Contents
loading

Table of Contents