Basic Multi-Point Installation Distances - Lucent Technologies definity Installation Manual

Enterprise communications server
Hide thumbs Also See for definity:
Table of Contents

Advertisement

DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets 555-230-128
1
Install and Cable the Cabinets
Install Multi-point Adapters

Basic Multi-point Installation Distances

Figure 1-38
installations. In
closet. All distances assume 24 AWG (#5) (0.26 mm
6
1
Figure Notes
1. S-interface source (TN556)
2. Terminating resistor
3. Satellite closet
4. Maximum distance from
S-interface source to work location
(1600 feet) (488 m)
5. Maximum distance from satellite
closet to work location (250 feet)
(76 m)
Figure 1-38. Basic Multi-point with One Work Location
provides cabling information for fanout of ISDN-BRI multi-point
Figure
1-38, the terminating resistor is located in the satellite
4
2
3
2
) D-Inside Wire (DIW).
11
10
11
5
6. System cabinet
7. Terminating endpoint 1
8. Terminating endpoint 2
9. Work location
10. Maximum distance from information
outlet to terminating endpoint (33
feet) (10 m)
11. Information outlet
Issue 3
May 1998
Page 1-83
9
7
8
inst_dis RPY 012098