DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets 555-230-128
1
Install and Cable the Cabinets
Activate and Administer the System
Log into the System
1. Verify the screen displays: Login:
2. Type craft and press
3. Type crftpw and press
The screen displays the system software version and the terminal types.
Terminal Type (513, 715, 4410, 4425, VT220): [513]
4. Enter the type of management terminal (such as 715) and press
Check System Status
The system status may suggest problem areas. Refer to DEFINITY Enterprise
Communications Server Release 6 Maintenance for R6csi .
1. Type status system all-cabinets and press
2. Verify the screen displays a service state of in for all appropriate areas.
Change Customer Options
Refer to DEFINITY Enterprise Communications Server Release 6 Administration
and Feature Description to view a sample screen.
The following features are part of the basic software package and do not require
activation. They default to y (yes) on the Optional Features form.
ARS/AAR Partitioning
Emergency Access to Attendant
Hospitality (Basic)
Service Observing
NOTE:
An init login is required to change customer options. Contact your regional
CSA (Customer Software Administrator) to perform this function.
1. Enter change system-parameters customer-options and press
2. Using the customer order, enable the optional features purchased by the
customer (as shown by PEC codes on the customer order).
3. Press
4. Logoff and then log back in to affect the customer option changes.
.
Enter
. The password does not display as it is typed.
Enter
when finished to submit the form.
Enter
May 1998
Page 1-47
Enter
.
Enter
Enter
Issue 3
.
.
Need help?
Do you have a question about the definity and is the answer not in the manual?
Questions and answers