DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets 555-230-128
1
Install and Cable the Cabinets
Activate and Administer the System
Circuit Pack Administration
After the equipment is installed (including circuit packs), the circuit packs must
be administered. Refer to DEFINITY Enterprise Communications Server
Release 6 Administration and Feature Description, for more information.
The following describes general administration information:
Use the Circuit Packs form to administer circuit packs to carrier slots. The
circuit packs must be installed (or assigned using the Circuit Packs form)
before administering voice terminals, attendant consoles, or trunks.
Each page of the form represents 1 carrier in the cabinet shown on the
command line. For Release 6 CMC, all carriers and slots appear even if
they are not included in the hardware.
It is not necessary to fill in the Circuit Packs form if the circuit packs are
installed at the time of administration.
Refer to DEFINITY Communications System Generic 3 Planning and
Configuration , 555-230-601, for more information about circuit pack
administration and port assignment records (the DS1 circuit pack and
translation are covered in Chapter 2 and Chapter 3).
For initial installation, assign circuit packs to slots using the hardware
configuration layout record from the factory or Customer Services
Organization. Do not arbitrarily assign circuit packs to slots.
When a circuit pack in a slot differs from what has been administered on
the form, a "#" displays between the "Sfx" and "Name" fields.
Set System Maintenance Parameters
!
CAUTION:
To prevent unnecessary trouble tickets, do not enable the system alarms (Alarm
Origination feature) until all installation and administration procedures are completed.
1. Enter change system-parameters maintenance and press
2. Enter the alarm notification and scheduled maintenance information into
each field on Page 1 of the form.
3. Enter the appropriate information on Page 2 of the form.
4. Page 3 of the form is administered later in this book.
5. Press
when finished.
Enter
Issue 3
May 1998
Page 1-53
.