Installing The 1.8 Inch Usata Ssd Backplane - Dell PowerEdge C4130 Owner's Manual

Hide thumbs Also See for PowerEdge C4130:
Table of Contents

Advertisement

3.
Keep the Torx T10 screwdriver ready.
4.
Remove both the SSD carriers.
5.
Remove the 1.8 inch SSD cage.
CAUTION: To prevent damage to the drives and backplane, you must remove the SSD carriers
from the system before removing the backplane.
CAUTION: You must note the number of each SSD and temporarily label them before removal so
that you can replace them in the same locations.
Steps
1.
Remove the screw securing the SSD backplane to the SSD cage.
2.
Remove the SSD backplane from the slot on the SSD cage.
Figure 60. Removing the 1.8 inch SSD backplane
1.
screw
3.
tab on the SSD backplane
5.
SSD cage
Related Links
Safety instructions
Before working inside your system

Installing the 1.8 inch uSATA SSD backplane

Installing the 1.8 inch uSATA SSD backplane
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
1.
Follow the safety guidelines listed in the Safety instructions section.
2.
Follow the procedure listed in before working inside your system.
2.
SSD backplane
4.
slot on the SSD cage
137