Chassis weight

Table 9. Chassis weight
System
PowerEdge C4130

Processor specifications

The PowerEdge C4130 system supports up to two Intel Xeon E5-2600 v4 product family processors.

PSU specifications

Table 10. PSU specifications
PSU
Class
1100 W AC
Platinum
1600 W AC
Platinum
2000 W AC
Platinum
NOTE: Heat dissipation is calculated by using the PSU wattage rating.
NOTE: This system is also designed to connect to the IT power systems with a phase to phase
voltage not exceeding 230 V.

System battery specifications

The PowerEdge C4130 system supports CR 2032 3.0-V lithium coin cell system battery.

Expansion bus specifications

The PowerEdge C4130 system supports PCI express (PCIe) generation 3 expansion cards, which need to
be installed on the system board by using expansion card risers. This system supports four expansion card
riser configurations. The following table provides detailed information about the expansion card riser
configurations:
Table 11. Expansion card riser configurations
Expansion card
PCIe slots on the
riser
riser
Slot 1
Configuration 1
Slot 2
24
Maximum weight
20.2 kg (44.53 lb)
Heat dissipation
Frequency
(maximum)
4100 BTU/hr
50/60 Hz
6000 BTU/hr
50/60 Hz
7500 BTU/hr
50/60 Hz
Height
Length
half height
half Length
half height
half Length
Voltage
100–240 V AC,
autoranging
200–240 V AC,
autoranging
200–240 V AC,
autoranging