Figure 6. AC PSU status indicator
1.
AC PSU status indicator/handle
Table 6. AC PSU status indicators
Convention
Power indicator
pattern
A
Green
B
Flashing green
C
Flashing green
and turns off
D
Flashing amber
Condition
A valid power source is connected to the PSU and the PSU is
operational.
When the firmware of the PSU is being updated, the PSU handle
flashes green.
When hot-adding a PSU, the PSU handle flashes green five times at
4 Hz rate and turns off. This indicates a PSU mismatch with respect
to efficiency, feature set, health status, and supported voltage.
NOTE: Ensure that both the PSUs are of the same capacity.
CAUTION: For AC PSUs, use only PSUs with the Extended
Power Performance (EPP) label on the back.
NOTE: Mixing PSUs from previous generations of Dell
PowerEdge servers can result in a PSU mismatch condition or
failure to turn the system on.
Indicates a problem with the PSU.
CAUTION: When correcting a PSU mismatch, replace only the
PSU with the flashing indicator. Swapping the PSU to make a
matched pair can result in an error condition and unexpected
system shutdown. To change from a high output
configuration to a low output configuration or vice versa, you
must power down the system.