Code
Contents
9140
Sensor error in coin vender
change (Yen 100)
Change is empty despite
change is enough.
9150
Sensor error in coin vender
change (Yen 500)
Change is empty despite
change is enough.
9160
Coin vender pay-out error
Coin is paid out despite the
pay-out motor is determined
not active.
9170
Coin vender pay-out sensor
error
Coin is paid out despite the
pay-out motor is determined
not active.
9500
ISC PWB error A
ISC PWB error B
9510
Related parts
Coin jam in the
Check visually and remedy.
change tube
Contact in the
Check the connection of the empty change
connector
sensor.
Change empty
Replace the coin mec.
sensor
Coin vender control
Replace the coin mec.
PWB
Change tube
Check no exchange jam is observed at the
outlet and, if necessary, repair it.
Contact in the
Check the connection of the empty change
connector
sensor.
Change empty
Replace the coin mec.
sensor
Coin vender control
Replace the coin mec.
PWB
Pay-out motor
Replace the coin mec.
Pay-out area
Check no exchange jam is observed at the
outlet and, if necessary, repair it.
Pay-out motor
Replace the coin mec.
Pay-out sensor
Replace the coin mec.
Main PWB
ISC PWB
Main PWB
DP SHD PWB
1-4-67
Check procedures/
corrective measures
1. Reinsert the connector if its connection
is loose.
Main PWB (YC25) and ISC PWB (YC4)
2. Replace the main PWB (see page 1-5-
38).
3. Replace the ISC PWB
4. Contact the Service Support.
1. Reinsert the connector if its connection
is loose.
DP relay PWB (YC2) and DP SHD PWB
(YC3)
2. Replace the main PWB (see page 1-5-
38).
3. Replace the DP SHD PWB.
4. Contact the Service Support.