Item No.
U411
Method: [Table (Chart2)]
1. Enter the target values which are shown on the back of the specified original
(P/N: 302FZ56990) executing maintenance item U425.
2. Set a specified original on the platen.
3. Enter maintenance item U411.
4. Select [Target].
5. Select [U425] and press the start key.
6. Select [Table (Chart2)].
7. Select the item.
All
Input
C.A.
MTF
Gamma
Matrix
8. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning.
Method: [DP FaceUp (Chart2)]
1. Set a specified original (P/N: 302AC68243) on the DP.
Cut the trailing edge of the original.
2. Enter maintenance item U411.
3. Select [Target].
4. Select [U425] and press the start key.
5. Select [DP FaceUp (Chart2)].
6. Select [INPUT].
Input
Display
Executing the all scanner adjustment
Executing the adjustment for magnification, leading edge tim-
ing and center line
Executing the adjustment for chromatic aberration filter
Executing the adjustment for MTF filter
Executing the adjustment for input gamma
Executing the adjustment for matrix
Display
Executing the adjustment in the DP scanning section (first
side) for magnification, leading edge timing and center line
Description
Description
74 ± 1 mm
Figure 1-3-40
Description
1-3-122
2NL/2P8-3
5 mm
149 ± 1 mm

Hide quick links: