U411
All
LED/AGC
White
Input
C.A.
MTF
Gamma
Matrix
7. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning.
* : If the target values are not obtainable automatically, manually enter the following target
values in the following manner and perform adjustment.
1. Enter the target values which are shown at the bottom of the specified original
(P/N: 7505000005) executing maintenance item U425.
2. Set a specified original on the platen.
3. Enter maintenance item U411.
4. Select [Target].
5. Select [U425] and press the start key.
6. Select [Table (Chart1)].
7. Select the item.
* : Select All for normal use.
8. Press the start key. Auto adjustment starts.
Method: [DP FaceUp (Chart1)]
To automatically enter the target value
1. Set a specified original (P/N: 7505000005) on the DP face up.
2. Enter maintenance item U411.
3. Select [Target].
4. Select [Auto] and press the start key.
5. Select [DP FaceUp (Chart1)].
6. Select [Input].
Input
7. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning.
Display
Executing the all scanner adjustment
Executing the adjustment for LED light quantity/AGC
Executing the white reference compensation coefficient
Executing the adjustment for magnification, leading edge tim-
ing and center line
Executing the adjustment for chromatic aberration filter
Executing the adjustment for MTF filter
Executing the adjustment for input gamma
Executing the adjustment for matrix
Display
Executing the adjustment for input gamma and matrix
Description
Description
Description