3210 Cis Lamp Error; 3220 Led Error - Kyocera TASKalfa 3510i Service Manual

Hide thumbs Also See for TASKalfa 3510i:
Table of Contents

Advertisement

Code
Contents
3210
CIS lamp error
When input value at the time
of CIS illumination does not
exceed the threshold value
between 5 s.
LED error
3220
The threshold is calculated for
colors at initialization and the
pixel which does not exceed
that value is greater than 200.
It is 1000 or more at the time of
market mode.
Related parts
CIS
DPSHD PWB
Replace the DPSHD PWB.
DP relay PWB
Replace the DP relay PWB.
CIS
ISC PWB
Replace the ISC PWB and execute U411
(see page 1-5-51).
Main PWB
Replace the main PWB (see page 1-5-38).
1-4-30
Check procedures/
corrective measures
1. Execute U906 Separating Operation
Release (see page 1-3-168).
2. Execute CIS of U061 lamp check (see
page 1-3-40).
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
CIS and DPSHD PWB (YC2)
DPSHD PWB (YC3) and DP relay PWB
(YC2)
4. If the wiring is disconnected, shorted or
grounded, replace the wiring.
5. Replace the CIS and execute U091 and
U411 (see page 1-3-55,1-3-119).
1. Execute CIS of U061 lamp check (see
page 1-3-40).
2. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
LED lamp PWB and ISC PWB (YC6)
ISC PWB (YC3) and Main PWB (YC11)
3. If the wiring is disconnected, shorted or
grounded, replace the wiring.
4. If the LED lamp won't light, replace the
LED PWB and execut U411 (see page
1-3-119).