The Digital Servo Amplifiers Of The Series Servostar 600; Operation Directly From Supply - Kollmorgen SERVOSTAR 601 Assembly And Installation Manual

Digital servo amplifier
Hide thumbs Also See for SERVOSTAR 601:
Table of Contents

Advertisement

General
1.4.2

The digital servo amplifiers of the series SERVOSTAR 600

Servoamplifiers of the SERVOSTAR 640/670 series are described in additional manuals.
Standard version
l
l
l
l
l
l
l
Open architecture
l
l
l
l
Options
l
l
l
l
l
l
l
l
l
1.4.3

Operation directly from supply

Electrical supply
l
l
l
Auxiliary supply voltage 24VDC
l
Power input filter
l
l
14
6 current ratings (1.5 A -Europe only-, 3 A , 6 A , 10 A , 14 A, 20 A)
three instrument widths :
wide range of rated voltage (3x208V
shield connection directly at the servo amplifier
two analog setpoint inputs
integrated CANopen (default 500 kBaud), for integration into CAN bus systems and for
setting parameters for several amplifiers via the PC-interface of one amplifier
integrated RS232, electrically isolated, integrated pulse-direction interface
open hardware and software architecture
slot for an expansion card
integrated macro language, including compiler
prepared for all conceivable customer-specific extensions
built-in safety relay (personnel-safety starting lock-out), ð p. 63
-AS-
I/O expansion card, ð p. 68
PROFIBUS DP expansion card, ð p. 72
SERCOS expansion card, ð p. 74
DeviceNet expansion card, ð p. 76
Ethernet expansion card, ð p. 78
Single Axis Controller expansion card, ð p. 80
-2CAN- Expansion module, separated connectors for CAN bus and RS232, ð p. 84
Third party expansion cards (ModBus, FireWire, LightBus etc. - contact distributors for further
information)
Directly off grounded 3 phase system,
230V
... 480V
-10%
208V
... 480V
-10%
TN-system or TT-system with grounded neutral point, max. 5000 rms symmetrical amperes.
Connection to other mains supply networks only with insulating transformer ð p. 16
Fusing (e.g. fusible cutout) provided by the user
single-phase supply (e.g. for setup) is possible
Electrically isolated, internal fusing (3.15 AT), from an external 24VDC psu, e.g. with insulating
transformer
Interference suppression filter for the supply input (to Class A) is integrated
Interference suppression filter for the 24V aux. supply (to Class A) is integrated
03/04
70 mm for 1.5A up to 10A rated current
100 mm for 14A rated current
120 mm for 20A rated current
to 3x480V
–10%
+10%
, 50 Hz,
+10%
, 60 Hz
®
SERVOSTAR
601...620 Installation Manual
Kollmorgen
+10%
)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Servostar 620

Table of Contents