6.1
Transport, storage, maintenance, disposal
Transport :
Packaging :
Storage :
Maintenance :
Cleaning :
Disposal :
®
SERVOSTAR
601...620 Installation Manual
03/04
— only by qualified personnel
— only in the manufacturer's original recyclable packaging
— avoid shocks
— temperature –25 to +70°C (-13...158°F), max. 20K/hr rate of change
— humidity
max. 95% relative humidity, no condensation
— the servo amplifiers contain electrostatically sensitive components which can
—
be damaged by incorrect handling
—
Discharge yourself before touching the servo amplifier. Avoid contact with
—
highly insulating materials (artificial fabrics, plastic films etc.).
—
Place the servo amplifier on a conductive surface.
— if the packaging is damaged, check the unit for visible damage.
—
In this case, inform the shipper and the manufacturer.
— cardboard box, can be recycled
— Dimensions: SERVOSTAR 601-610
SERVOSTAR 614/620
— Labeling : nameplate outside at the box
— only in the manufacturer's original recyclable packaging
— the servo amplifiers contain electrostatically sensitive components which can
—
be damaged by incorrect handling
—
Discharge yourself before touching the servo amplifier. Avoid contact with
—
highly insulating materials (artificial fabrics, plastic films etc.),
—
Place the servo amplifier on a conductive surface.
— max. stacking height
— storage temperature
— humidity
— storage duration
— the servo amplifiers do not require any maintenance
— opening the enclosure invalidates the warranty
— if the casing is dirty, clean with Isopropanol or similar cleaning agent
Do not immerse or spray.
— dirt inside the unit must be cleaned by the manufacturer
— dirty protective grill (fan) may be cleaned with a dry brush
— the servo amplifier can be reduced to its principal components by removing
the screws (aluminum heat sink and front panel steel housing sections,
electronics boards)
— disposal should be carried out by a certified disposal company.
—
We can give you suitable addresses.
(HxWxD) 125x415x350 mm
(HxWxD) 170x415x350 mm
8 cartons
–25 to +55oC(-13...131°F),
max.20K/hr. rate of change
relative humidity max. 95%, no condensation
< 1 year without restriction
> 1 year : capacitors must be re-formed before
setting up the servo amplifier.
To re-form, remove all electrical connections, and
supply the servo amplifier for about 30 min. from
230VAC, single-phase, on terminals L1 / L2.
Appendix