Kollmorgen
5.5.3

Connection technology

Cable selection, cable routing, shielding, bus connector, bus termination and transmission times are
all described in the "DeviceNet specification, volumes I, II, release 2.0", published by ODVA
5.5.4

Connection diagram

AGND and DGND (connector X3) must be joined together!
5.5.5

Combined Module/Network Status LED

LED is
off
green
flashing
green
flashing
red
red
®
SERVOSTAR
601...620 Installation Manual
SERVOSTAR 600
To indicate:
Device is not online.
The device has not completed the Dup_MAC_ID test yet.
The device may not be powered.
The device is operating in a normal condition and the device is online with connections in the estab -
lished state.
- The device is allocated to a Master
The device is operating in a normal condition and the device is online with no connections in the
established state.
The device has passed the Dup_MAC_ID test, is online, but has no established connections to ot -
her nodes.
This device is not allocated to a master.
Configuration missing, incomplete or incorrect.
Recoverable fault and/or one or more I/O Connections are in the Timed–Out state.
- The device has an unrecoverable fault; may need replacing.
- Failed communication device. The device has detected an Error that has rendered it incapable of
communicating on the network (e.g. Duplicate MAC ID, or Bus–off).
Extensions / Accessories