Port Configuration; Query The Rs-232 Mode; Change Rs-232 Mode; Query The Rs-232 Port Settings - Lightware HDMI-TPS-TX210 User Manual

Hide thumbs Also See for HDMI-TPS-TX210:
Table of Contents

Advertisement

7.4. RS-232 port configuration

7.4.1. Query the RS-232 mode

Description: The RS-232 mode can be queried as follows:
Command {RS232=?}
Response (RS232=<mode>)CrLf
Legend:
Explanation: Current RS-232 mode is Control mode.

7.4.2. Change RS-232 mode

Description: The RS-232 mode can be changed as follows:
Command {RS232=<mode>}
Response (RS232=<mode>)CrLf
Legend: See section
Explanation: The RS-232 mode is set to Pass mode.

7.4.3. Query the RS-232 port settings

Description: The RS-232 port settings can be queried as follows:
Command {RS232_LOCAL_FORMAT=?} → {rs232_local_format=?}
Response (RS232_LOCAL_FORMAT=
Legend:
Explanation1: Current RS-232 settings on local port: Baud rate is 57600, 8 data bits, no
parity, 1 stop bit.
Command {RS232_LINK_FORMAT=?} → {rs232_link_format=?}
Response (RS232_LINK_FORMAT=
Legend: Same as above.
Explanation2: Current RS-232 settings on link port: Baud rate is 9600, 8 data bits, no
parity, 1 stop bit.
Section 7. LW2 Programmer's reference
Format
<mode>:
CONTROL = Control mode is enabled,
PASS = Pass mode is enabled,
CI = Command injection mode is enabled.
Format
7.4.1
on page 69.
Format
<baud>;<data bits>; <parity>;
<stop bits>)CrLf
<baud>:
Baud rate which can be 4800, 7200, 9600, 14400, 19200,
38400, 57600, 115200
<data bits>: 8 or 9
<parity>:
N (none), O (odd), E (even)
<stop bits>: 1, 1.5, 2
Format
<baud>;<data bits>;
<parity>; <stop bits>)CrLf
HDMI-TPS-TX200 series
Example
→ {rs232=?}
← (RS232=CONTROL)CrLf
Example
→ {rs232=pass}
← (RS232=PASS)CrLf
Example1
← (RS232_LOCAL_FORMAT=57600;
8;N;1)CrLf
Example2
← (RS232_LINK_FORMAT=9600;
8;N;1)CrLf
User's Manual