Function Buttons; Advanced View - Lightware HDMI-TPS-TX210 User Manual

Hide thumbs Also See for HDMI-TPS-TX210:
Table of Contents

Advertisement

6.10.4. Function buttons

Info: Please note that the data collecting may take some minutes. You will be prompted about
log generating before starting.

6.11. Advanced view

Advanced view is the surface for LW3 protocol tree with terminal window. Commands and
specific parameters (which are not available on the user interface) can be run and set.
Detailed information about the protocol, nodes, methods and parameters can be found in
chapter
1
2
3
1
Terminal window
Command line
2
3
Protocol tree
Node list
4
Page 60 / 122
System log button: Logged events can be collected and saved into a file which is
useful when troubleshooting or in other special case for analyzing. When the
collecting is done, the Save as window appears; select the desired location and
press the Save button.
Factory defaults button: Factory default values can be restored by pressing the
button; you will be asked to confirm. The connection will be terminated and the
device is rebooted. Factory default values are listed in section
Reboot button: The device can be restarted; the connection will be terminated.
8
on page 77. Click on Close button to hide the Advanced view.
Commands and responses with time and date are listed in this
window. Sent command is displayed in red and starts with '>'
character, received response is displayed in blue and starts with '<'
character. The content of the window can be emptied by the Clear
button. If the Autoscroll option is ticked, the list is scrolled
automatically when a new line is added.
Type the desired command and execute it by the Send button.
LW3 protocol tree; select an item to see its content.
Correspondent parameters and nodes are shown which are
connected to the selected item in the protocol tree.
Manual button: Manual (short description) of the node can be
Set button:
Call button:
Section 6. Software control – using Lightware Device Controller (LDC)
called and displayed in the terminal window. See
more information about manuals in section
on page 84.
Saves the value/parameter typed in the textbox.
Calls the method, e.g. reloads factory default
settings.