Installing Core I/O Cards - HP AB464-9003F Service Manual

Hpe integrity rx6600 server user
Table of Contents

Advertisement

Shell> info io
I/O INFORMATION
BOOTABLE DEVICES
Order
-----
1
2
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C5000034749D,Lun0)/HD(Part1,Sig4EE76936-BE45-47FA-9AC7-B0ECF2D912F2)
3
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C50000347735,Lun0)/HD(Part1,Sig92C8CB4C-E0F2-11DA-8002-D6217B60E588)
4
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C50000347735,Lun0)/HD(Part3,Sig92C8CB7E-E0F2-11DA-8004-D6217B60E588)
Seg
Bus
#
#
---
---
00
00
00
00
00
00
00
00
00
00
00
00
00
14
00
14
00
15
00
15
00
15
00
15
Fast initialization: Enabled
System Wake-On-LAN:
Shell>
Devices, such as USB ports, that do not occupy a slot are referenced as being in slot XX.
Slots that do not contain an I/O card will not be listed in the output. Using the output, confirm
that a device detected in each slot that is populated.
13. Installing the OS
HP-UX, Windows, and Linux require reinstallation of the OS with the upgrade of the IOBP.
See
Figure 89 (page 263)
14. Booting to the Operating System
See
Chapter 4 (page 117)

Installing Core I/O Cards

WARNING!
components to cool before touching them.
CAUTION:
information and user documentation provided with the server before attempting the installation.
Many servers are capable of producing energy levels that are considered hazardous and are
intended to be serviced only by qualified personnel who have been trained to deal with these
hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided
for the purpose of removing these hazardous conditions.
CAUTION:
you are properly grounded before beginning this procedure.
CAUTION:
rack are stable before beginning the installation procedure.
268 Upgrades
Media Type
Path
----------
---------------------------------------
CDROM
Acpi(HWP0002,PNP0A03,0)/Pci(2|1)/Usb(0, 0)/CDROM(Entry0)/HD(Part1,Sig00000000)
HARDDRIVE
HARDDRIVE
HARDDRIVE
Dev
Fnc
Vendor
Device Slot
#
#
ID
ID
---
---
------
------
01
00
0x103C
0x1303
01
01
0x103C
0x1302
01
02
0x103C
0x1048
02
00
0x1033
0x0035
02
01
0x1033
0x0035
02
02
0x1033
0x00E0
01
00
0x1000
0x0054
02
00
0x1000
0x0054
01
00
0x1000
0x000F
01
01
0x1000
0x000F
02
00
0x8086
0x1079
02
01
0x8086
0x1079
Enabled
for more information.
for this procedure.
To reduce the risk of personal injury from hot surfaces, allow the internal system
To reduce the risk of personal injury or damage to the equipment, consult the safety
Electrostatic discharge (ESD) can damage electronic components. Be sure that
When working with equipment installed in a rack, be sure that the equipment and
#
Path
---
-----------
XX
Acpi(HWP0002,PNP0A03,0)/Pci(1|0)
XX
Acpi(HWP0002,PNP0A03,0)/Pci(1|1)
XX
Acpi(HWP0002,PNP0A03,0)/Pci(1|2)
XX
Acpi(HWP0002,PNP0A03,0)/Pci(2|0)
XX
Acpi(HWP0002,PNP0A03,0)/Pci(2|1)
XX
Acpi(HWP0002,PNP0A03,0)/Pci(2|2)
01
Acpi(HWP0002,PNP0A03,400)/Pci(1|0)
02
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)
07
Acpi(HWP0002,PNP0A03,500)/Pci(1|0)
07
Acpi(HWP0002,PNP0A03,500)/Pci(1|1)
08
Acpi(HWP0002,PNP0A03,500)/Pci(2|0)
08
Acpi(HWP0002,PNP0A03,500)/Pci(2|1)

Advertisement

Table of Contents
loading

Table of Contents