HP AB464-9003F Service Manual page 291

Hpe integrity rx6600 server user
Table of Contents

Advertisement

Pred Fail
Size (MB)
Manage Array Screen
The Manage Array screen enables you to manage the current array. To access the Manage
Array screen, select the appropriate field and press Enter on the Manage Array field from the
View Array screen.
The Manage Array screen enables you to perform the following actions:
Manage Hot Spare
To display a Hot Spare Management screen that has the same layout as the Create New Array
screen, press Enter on Manage Hot Spare. This field is grayed out under the following conditions:
The array is inactive.
The array is at its maximum number of devices.
Non-IR firmware is used.
IR is disabled. The array is inactive.
Failed
Disk has failed.
Initalizing
Disk is initializing.
CfgOffln
Disk is offline at host's request.
User Fail
Disk is marked failed at host's request.
Offline
Disk is offline for some other reason.
Inactive
Disk has been set inactive.
Not Syncd
Data on disk is not synchronized with the rest of
the array.
Primary
Disk is the primary disk for a 2 disk mirror and is
OK.
Secondary
Disk is the secondary disk for a 2 disk mirror and
is OK.
Wrg Type
Device is not compatible for use as part of an IM
array.
Too Small
Disk is too small to mirror existing data.
Max Dsks
Maximum # of disks allowed for this type of Array
reached and/or Maximum # of total IM disks on a
controller reached.
No SMART
Disk doesn't support SMART, cannot be used in
an RAID array.
Wrg Intfc
Device interface (SAS) differs from existing IM
disks.
Indicates whether device SMART is predicting device failure (Yes,
No).
Indicates the size of the device in megabytes (megabyte = 1024 x
1024 = 1,048,576). If the device is part of a two-disk array, this field
reflects the size of the array, not the size of the individual disk. If the
device is part of a three or more disk array, this field is the size that
the disk makes up within the array. When creating a striped array,
the usable size of the array is determined by the number of drives
times the size of the smallest drive in the array. In arrays consisting
of different sized drives, excess space on larger drives are unusable.
HPE 8 Internal Port SAS HBA (SAS Controller) 291