Connecting External Storage; Sas Cable Part Numbers; Saupdate Utility - HP AB464-9003F Service Manual

Hpe integrity rx6600 server user
Table of Contents

Advertisement

Depending on the OS, additional device drivers and management agents must be installed. See
the User guide for the specific HPE Smart Array Controller on the Hewlett Packard Enterprise
website at http://www.hpe.com/info/integrity-iocards-docs under the specific Smart Array
Controller product for installation procedures.
The latest firmware, drivers, utilities, software, and documentation for Integrity servers are available
on the support page of the Hewlett Packard Enterprise website at http://www.hpe.com/support/
itaniumservers.

Connecting External Storage

IMPORTANT:
To connect external storage, follow these steps:
1.
Power off the server.
2.
Connect an external SAS cable to the external port of the controller.
NOTE:
the controller preferentially discovers devices attached to port 1E. However, drives on the
shared internal port are unavailable until you disconnect the external storage device.
3.
Tighten the lock screws on the cable connector.
4.
Attach the other end of the cable to the SAS input connector of the external storage enclosure.
IMPORTANT:
either all SAS or all SATA. (Parallel SCSI drives cannot be used with this controller.)
5.
Tighten the lock screws on the cable connector.
6.
Power on the enclosure.
7.
Power on the server.

SAS Cable Part Numbers

If you require additional cables, order them by the option kit number listed in
Table 35 SAS Cable Part Numbers
Cable Length
1.0 m (3.3 ft.)
2.0 m (6.6 ft.)
4.0 m (13 ft.)
6.0 m (20 ft.)

SAUPDATE Utility

Use saupdate from the EFI Shell to update the firmware image on the Smart Array Controller.
Command line options are described below. Follow one of these two procedures to run saupdate:.
If you are using saupdate from the Offline Diagnostic CD:
1.
Download the firmware and copy it to the EFI partition.
2.
The CD containing saupdate.efi must be in the drive before booting the system to allow
device mapping.
3.
Boot the system to the EFI Shell prompt. The CD drive should appear in the list of mapped
devices as fs0.
4.
Change to this device by entering fs0: under the EFI Shell prompt.
104 Installing the System
Not all OSs support external drives.
You do not have to disconnect any internal drives on shared internal port 1I because
Drives that are to be used in the same array must be of the same type,
Option Kit Number
389664-B21
389668-B21
389671-B21
389674-B21
Table
Cable Assembly Number
361317-001
361317-002
361317-004
361317-006
35.

Advertisement

Table of Contents
loading

Table of Contents