HP AB464-9003F Service Manual page 290

Hpe integrity rx6600 server user
Table of Contents

Advertisement

Size (MB)
View Array Screen
The View Array screen enables you to view the current array configuration. To access the View
Array screen, press Enter on the View Existing Array field from the Select New Array Type
screen.
You can perform the following actions on the View Array screen:
To view the next array, press N.
To create a new array, press C.
Array
Identifier
Type
Scan Order
Size (MB)
Status
Bay
Device Identifier
RAID Disk
Hot Spr
Drive Status
290 Core I/O Card Utilities
Indicates the size of the device in megabytes (megabyte = 1024 x
1024 = 1,048,576). If the device is part of a two-disk array, this field
reflects the size of the array, not the size of the individual disk. If the
device is part of a three or more disk array, this field is the size that
the disk makes up within the array. When creating a striped array,
the usable size of the array is determined by the number of drives
times the size of the smallest drive in the array. In arrays consisting
of different sized drives, excess space on larger drives are unusable.
Displays the number of this array.
Displays the identifier of this array.
Displays the RAID type.
Displays the scan order of the array.
Displays the size of the array.
Displays the status of the array.
Displays the bay in which devices are located.
Displays the device identifier.
Specifies the devices (disks) that make up an IM array. If RAID Disk
is Yes, the device is part of an IM array, if No, the device is not part
of an IM array. This field is grayed out under the following conditions:
The device does not meet the minimum requirements for use in
an IM array.
The device is not large enough to mirror existing data on the
primary drive.
This disk has been selected as the hot spare for the IM array.
Specifies whether a device is the hot spare for an IM array. If hot
spare is Yes, the device is used as a hot spare for the IM array, if No,
the device is not used as a hot spare for the IM array. Only one hot
spare per IM array is permitted. A hot spare is not required in an IM.
A hot spare can be specified at array creation, or any time after
creation, provided the array is made up of 5 disks or fewer. This field
is grayed out under the following conditions:
The device does not meet the minimum requirements for use in
an IM array.
The array already has a hot spare.
The array is made up of the maximum number of devices (6).
The device isn't large enough to mirror existing data on the
primary. The hot spare drive must be greater than or equal to
the size of any drive in any IM volume.
xxxx
OK
Disk is online and fully functional.
Missing
Disk is not responding.

Advertisement

Table of Contents
loading

Table of Contents