< Example of Printed Image >
Copy Image Leading Edge
Skewed to
the right
A
Space
Scanning Glass
Guide
Scanning Glass
Left Platen Cover
Screws
Screws
(Silver)
(Silver)
Scanning Glass Guide
Ver. 1.2
(15) Using a lined original (about 20lb (80 g/m
(16) Check the printed copy. If the printed image is skewed
B
A
A
(17) Check for spacing between the i-ADF / ADF and the
ADF Unit
(18) If there is no spacing, adjust the Platen Glass
307
paper), make a copy from the i-ADF / ADF to check
for feeding alignment.
either to the Right or Left, adjust the i-ADF / ADF
position following the procedure below:
A. Loosen the 5 Screws securing the i-ADF / ADF.
B. Using the Hallmark on the Right Hinge Base and
the ADF Mounting Bracket as a guide, shift the
i-ADF / ADF position following the procedure below:
• When the printed image is skewed to the right, shift
the i-ADF / ADF toward the front of the machine
slightly.
• When the printed image is skewed to the left, shift
the i-ADF / ADF toward the rear of the machine
slightly.
C. Tighten the 5 Screws loosened in step A..
D. Repeat step (15) to recheck the feeding alignment
and readjust the i-ADF / ADF position as needed.
Scanning Glass Guide as illustrated.
position following the procedure below:
A. Open the ADF Unit.
B. Remove 3 Screws (Silver).
C. Remove the Left Platen Cover.
D. Loosen 2 Screws.
E. Shift the Scanning Glass Guide to the left and
tighten the 2 Screws.
F. Reinstall the Left Platen Cover and secure it with 3
Screws (Silver).