No.
Parameter
045 Ring Detect
Count
046 On-Hook Time
047 Response Wait
Interval
048
Not Used
~
049
050 Ring Detect
Mode
051 Not Used
052 Pulse Rate
053
Not Used
~
054
055 Busy Tone
Check
056 Dial Tone Check 1 = Off
057 DC Loop Check
(Except for USA
and Canada)
058 Comm. JRNL +
Image
059 Confidential
RCV Report
060 Version
061 TX/RX/PRT/
CPY
062 Print Counter
063
Not Used
~
067
Ver.1.2
Function Parameter Table
Selections
1 = 1 ring
~
9 = 9 rings
0 = 0 sec.
~
90 = 90 sec.
1 = 1 sec.
~
90 = 90 sec.
20 ~ 150 sec.
(For France Only)
1 = Normal
2 = Rough
1 = 10 pps
2 = 20 pps
1 = Off
2 = On
2 = On
1 = Off
2 = On
1 = Off (without image)
2 = On (with image)
1 = Off (does not print out)
2 = On (prints out)
Indicates the Host software
version.
1 = Fax Transmit Count
2 = Fax Receive Count
3 = Total Count
4 = Copy Print Count
1 = Off
2 = On
Selects the ring detection count from 1 to 9 rings in
1 ring step intervals.
Selects the on-hook time between sequential
communication calls in 1 second step intervals.
Selects the waiting interval for the response after
completing the dialing.
Selects the quality of ringer detection. Use if the line
signal is out of regulation, set to "Rough" so that
the unit may detect the ringing signals.
Selects the dial pulse rate 10/20 pps.
Selects whether to detect the Busy Tone.
Selects whether to detect Dial Tone before dialing
the telephone number.
Selects whether the unit checks the DC Loop during
communication.
Selects whether the machine prints the COMM.
Journal with image.
Selects whether the machine prints the Confidential
RCV Report.
Displays the transmitted, received, total printed and
copied document count.
Selects whether to print in the Fax Parameter List,
the counter information that is displayed in the
Function Parameter No. 61.