Panasonic DP-8032 Service Manual page 159

Digital imaging systems
Hide thumbs Also See for DP-8032:
Table of Contents

Advertisement

Code
Mode
540
XMT ECM
541
XMT ECM
542
XMT ECM
543
XMT ECM
544
XMT ECM
550
RCV ECM
554
RCV ECM
555
RCV ECM
570
RCV
571
XMT
580
XMT
581
XMT
582
XMT
601
XMT
623
XMT
630 XMT or RCV
(Polling)
631
XMT
634
XMT
Ver. 1.2
Fax Information Codes
Phase
Description of Problem
B
No response after transmitting 3rd
CTC or DCN received.
D
No response after transmitting 3rd
EOR or received DCN.
D
No response to the 3rd RR
transmitted or received DCN.
D
T5 timer (60 sec.) elapsed without
MCF.
D
Stopped Transmission after EOR
Transmission.
C
Timer between frames in phase C
has elapsed.
D
Transmitted ERR after receiving
EOR.
D
Transmitted PIN after receiving
EOR.
B
Password or machine code did not
match during remote diagnostic
communication.
B
Remote unit did not have the
remote diagnostic function.
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
B
Sub-address SEP (for Polling)
transmission to a unit that has their
DIS bit 47 (NSF bit 130) OFF.
ADF Door was opened during ADF
transmission.
A
No original was in the ADF. (Built-
in dialer engaged)
B
Redial count over.
A
"STOP" key was pressed during
Auto Dialing.
PSTN Redial count over with no
response or busy tone was not
detected.
Note:
U.S.A. and Canadian models
will redial only once if a busy
tone is not detected.
Incompatible interface.
Faulty line.
MJR PCB abnormal.
Remote unit abnormal.
Remote unit abnormal.
Faulty line.
MJR PCB abnormal.
Defective remote station.
Faulty line.
Faulty line and Operator Call
requested by RX side.
Sub-address transmission to a unit that
has no Sub-address function.
Sub-address transmission to a unit that
has no Sub-address function.
Sub-address transmission to a unit that
has no Sub-address function.
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the
ADF.
No dial tone detected. Sensor dial tone
is not detected. (Country dependent)
Busy tone is detected. (Country
dependent) T1 timer (35±5 sec)
elapsed without a signal from the
receiver.
159
DP-8032/8025
Possible Cause(s)