Step
5.
Configure an output rule
for the SNMP module.
6.
Configure the timestamp
format.

Outputting system information to the Web interface

The Web interface only receives log information, and discards trap and debug information.
This feature allows you to control whether to output system information to the Web interface and, if so,
which system information can be output to the Web interface. The Web interface provides search and
sorting functions. You can view system information by clicking corresponding tabs after logging in to the
device through the Web interface.
To output system information to the Web interface:
Step
1.
Enter system view.
2.
Enable the
information center.
3.
Name the channel
with a specified
channel number.
4.
Configure an
output channel for
the Web interface.
5.
Configure an
output rule for the
Web interface.
Configure the
6.
timestamp format.
Command
info-center source { module-name |
default } channel { channel-number |
channel-name } [ debug { level severity
| state state } * | log { level severity |
state state } * | trap { level severity |
state state } * ] *
info-center timestamp { debugging |
log | trap } { boot | date | none }
Command
system-view
info-center enable
info-center channel channel-number
name channel-name
info-center syslog channel
{ channel-number | channel-name }
info-center source { module-name |
default } channel { channel-number |
channel-name } [ debug { level severity |
state state }* | log { level severity | state
state }* | trap { level severity | state
state }* ]*
info-center timestamp { debugging | log |
trap } { boot | date | none }
48
Remarks
Optional.
See
"Default output rules of system
information."
Optional.
The timestamp format for system
information is date by default.
Remarks
N/A
Optional.
Enabled by default.
Optional.
See
Table 2
for default channel names.
Optional.
By default, system information is output
to the Web interface through channel
6.
Optional.
See
"Default output rules of system
information."
Optional.
The timestamp format for system
information is date by default.