Step
11.
Configure the string to be
filled in the data field of
each probe packet.
12.
Configure the number of
probe packets to be sent
during each voice probe
operation.
13.
Configure the interval for
sending probe packets
during each voice probe
operation.
14.
Configure the interval the
NQA client must wait for a
response from the server
before it regards the
response times out.
15.
Configure optional
parameters.

Configuring DLSw tests

DLSw tests of an NQA test group are used to test the response time of a DLSw device.
Before you start DLSw tests, enable the DLSw function on the peer device.
To configure DLSw tests:
Step
1.
Enter system view.
2.
Enter NQA test group
view.
3.
Configure the test type
as DLSw, and enter test
type view.
4.
Configure the
destination address of
probe packets.
5.
Configure the source IP
address of probe
packets.
6.
Configure optional
parameters.
Command
data-fill string
probe packet-number
packet-number
probe packet-interval
packet-interval
probe packet-timeout
packet-timeout
See
"Configuring optional
parameters for an NQA test
group"
Command
system-view
nqa entry admin-name
operation-tag
type dlsw
destination ip ip-address
source ip ip-address
See
"Configuring optional
parameters for an NQA
test
group"
129
Remarks
Optional.
By default, the string is the hexadecimal
number 00010203040506070809.
Optional.
1000 by default.
Optional.
20 milliseconds by default.
Optional.
5000 milliseconds by default.
Optional.
Remarks
N/A
N/A
N/A
By default, no destination IP address is
configured.
Optional.
By default, no source IP address is specified.
The source IP address must be the IP address of a
local interface. The local interface must be up.
Otherwise, no probe packets can be sent out.
Optional.